Hi Experts,

We have bw on HANA with HA DB.we have configured HSR between PR and HA node. added hostname in both note hosts file.hsr-error-status.jpg

below are configuration in PR node. DATA & Key file to OR in SE node

1. global.ini/[system_replication]/enable_log_retention = on

2. global.ini/[inifile_checker]/replicate = true

3. log_mode=normal

Enable the ‘ini’ parameters and their values replication from the primary site to secondary site.

hdbnsutil -sr_enable --name=PR

hdbnsutil -sr_register --remoteHost=HANAnode1 --remoteInstance=00 --replicationMode=syncmem --name=SE --operationMode=logreplay

once we start replication its working and after full sync ,replication status change to logshpping_timeout_occurred.

we have tried below parameter but same issue

secondary Node change the the Parameter preload_column_tables = true to false

preload_column_tables = false
<a href="/storage/temp/2232696-hsr-error-status1.jpg" data-attachment="2232696">hsr-error-status1.jpg</a>[memorymanager]
global_allocation_limit = 600

can you please help.

Thanks in advance.

Accepted Solutions (0)

Answers (1)

Answers (1)

mamartins
Active Contributor
0 Kudos