Hello SAP expert,

I have the following situation. I have a storage type (RL05) for a rack storage. Most important settings for the storage type are:

  • Putaway rule 2: Addition to Existing Stock/Empty Bin
  • HU requirement X: HU is required
  • WT Generic 2: Only Storage type is suggested by the system (the workers in the warehouse want to choose the bin by themself...)
  • Mixed storage/Mixed storage in HUs: no restrictions
  • Level Add. to Stock H: Addition to Stock at Highest HU Level

Rest of the settings see screenshots:

ewmguy11_6-1712241100547.png ewmguy11_7-1712241115878.png

To the case:
For example I have the HU 810000167 with a quantity of 1 ton of the product 1000000058 on the bin RL05-01-01-01-03. ewmguy11_0-1712238312853.png

Then I get a new inbound delivery of the same product (or also another product) with maybe 0,5 tons and I want to put those 0,5 tons to the existing HU 810000167 and throw away the Handling Unit where the 0,5 tons were on. We are working with Handling Units 100% of the time and create the Handling Units already in the delivery with the Fiori App. And when doing the putaway to the existing HU, I get of course a nested Handling Unit. 

New inbound delivery with warehouse task of the product:

ewmguy11_2-1712240374143.png

Confirm the warehouse task in the foreground to the existing HU 810000167 which is already on the bin:

ewmguy11_3-1712240570242.png

Then the stock looks like this on the bin with a nested Handling Unit:ewmguy11_5-1712240841543.pngewmguy11_4-1712240788541.png

Is there a way to set up the system to delete the Handling Unit when adding it to another HU so I avoid that a nested Handling Unit is created?
What I would like to have as a result is only the HU 810000167 with a quantity of 1,5 tons. 

Thanks in advance!

Accepted Solutions (0)

Answers (1)

Answers (1)

bruce_huang
Employee
Employee
0 Kudos

Hi, 

From your example, you've created an HU WT for Qty 0.5 ton which leads to the nested HU. 

You should create the product WT instead.

 

BR,

Bruce Huang