BOMBOS Prerequisties (Data to be maintained in Enviromental Parameters of BOMBOS)
Hi,
Document on BOMBOS prerequisites to be maintained as environmental parameters this are the manadatory things before goto BOMBOS.
1. Assign materials to Specification to finished product and raw material.
2.Otherwise system will create specification and assign material automatically.
3.Other Details on
BOM BOS Interface | SCN
BOMBOS_ALTERNATIVE_TRANSFER |
0 |
ALL |
BOMBOS_AUTHGRP |
10 |
ALL |
BOMBOS_BOM_USAGE |
10 |
PROF001 |
BOMBOS_CMP_USAGE |
10 |
PROF001 |
BOMBOS_COMP |
1 |
SAP_EHS_1012_001 (Where you require BOS to execute) |
BOMBOS_COMP |
2 |
|
BOMBOS_COMP |
10 |
|
BOMBOS_COMPCAT |
10 |
ACT_AGENT (Component Type) |
BOMBOS_COMPREL |
10 |
ST |
BOMBOS_DEL_DATE |
0 |
20 |
BOMBOS_OWNID |
10 |
Get these from CVD5 data (Get number in BDT->Spec master-> Authorization group (assign CVD5 number here) Make it TEN digits by adding ‘0’ ex 456599 you have to give 0000456599 |
BOMBOS_PACKAGE_SIZE |
0 |
50 |
BOMBOS_RECURSIVE |
0 |
X |
BOMBOS_SRSID |
10 |
EH & S (Path BDT->Tools->import->Import and Export->Basic Settings for Import and Export ->Specify Data Orgin |
BOMBOS_SUBCAT |
1 |
PACKAGING |
BOMBOS_SUBCAT |
5 |
MAT_PART_E |
BOMBOS_SUBCAT |
6 |
REAL_SUB_E |
BOMBOS_SUBCAT |
7 |
REAL_SUB_E (Which Spec Type you need BOM BOS) |
BW_COMPOSITION_GET |
0 |
SAP_EHS_1012_001 (Where you require BOS to execute) |
Thanks
Satya
Dear Satya
well done. Thanks for sharing this information π π
C.B.
Dear Satya, C.B.,
During the BOM-BOS transfer in SAP EHSM Product Compliance, I receive the following error messages. Did you get the same errors during the initial set up? Do you know what is missing/incorrect?
Error 1. Invalid reference value in field COMPREL
Update -> Error 1 is fixed, by changing Parameter: BOMBOS_COMPREL to: PC (instead).
Error 2. Parent object contains error (could be caused by 1?)
Update -> Error 2 is fiex, by solving issue 1.
Error 3. Invalid reference value in field RVLID
Update -> Still an open issue.
--- Log file------
--- Log file------
Environmental Parameter settings:
Customizing checked:
Error 1:
Materials/components all contain unit of measure PC (piece) -> which cannot be converted to ST (item) by the standard user exists in Product Compliance. I have set up test BOM with UoM ST instead to avoid a warning message. I was hoping this would have solved error message 1 as well. I copied client 000 configuration for customizing activity: Environment, Health and Safety -> Basic Data and Tools -> Specification Management -> Specification Database Structure -> Component Settings -> Specify Reference Values for the Composition. What is missing?
MASS MASS Mass
MPROPO MPROPO Mass Proportion
VOL/VOL PROPOR Volume
VPROPO VPROPO Volume Proportion
W/W PROPOR Weight
Error 2: This is a very generic error message in the substance workbench, in case data cannot be copied correctly or in case of inconsitent data in the data tables. As I'm working on a full fresh system, I didn't expect this error. Could it be caused by error 1?
Error 3: Validity areas for Product Compliance are available as of client 000 (EHSM 6.2)
Thank you in advance.
Kind regards,
Roy
Update: Error 3 has been fixed as well. Issue was caused due to configuraiton: Specify Composition Group and Product Variants. The Product Variants configuration was configured incorrectly.
Hello Derks,
I am facing exactly this same error as yours "Error 3". Even knowing that your error has 4 years π
can you remenber what you changed in Product Variants configuration?
I have mine like the image attached.
Thank you
SΓ³nia
Hello
please generate own thread. For this "BOM BOS" varinat we have ( i believe) < 10 threads here.
Therefore. check Bill of Substance –Bill of material (BOSBOM)
and BOM BOS Interface
For Error 1:
Error 1:
Materials/components all contain unit of measure PC (piece) -> which cannot be converted to ST (item) by the standard user exists in Product Compliance. I have set up test BOM with UoM ST instead to avoid a warning message. I was hoping this would have solved error message 1 as well. I copied client 000 configuration for customizing activity: Environment, Health and Safety -> Basic Data and Tools -> Specification Management -> Specification Database Structure -> Component Settings -> Specify Reference Values for the Composition. What is missing?
MASS MASS Mass
MPROPO MPROPO Mass Proportion
VOL/VOL PROPOR Volume
VPROPO VPROPO Volume Proportion
W/W PROPOR Weight
You need first to understand the "EHS" approahc to handle compositiopns; then you need to understand, how BOMs are used/set up etc.
Error 2:
Error 2: This is a very generic error message in the substance workbench, in case data cannot be copied correctly or in case of inconsitent data in the data tables. As I'm working on a full fresh system, I didn't expect this error. Could it be caused by error 1?
=> we need more details => please create own thread.
Check: BOMBOS Error; may be if your read you will get a "story" to look at (even considering that this is "classi BOM BOS" But i belive your issue is on "same" level
C.B.
HI Derks,
Please check the customization and parent object due to customization.
Thanks
Satya