Calibration Process:

I had observed many queries related to calibration process steps,so please refer below which will support you. Thanks in Advance.

Master Data:

1.Create Equipment master-IE01

2.Create Task list -IA05

3.Create Maintenance plan-IP41

4.Schedule maintenance plan-IP10

Business Process :


Step-1 Deadline monitoring for maintenance plan (Transaction IP30)

step-1 Ip30.png

Enter the Maintenance plan and click continue                                                                                                                         

/wp-content/uploads/2015/06/display_729231.png

Then the plan schedule and automatically tiger the calibration Order Scheduling status was show in Message text. Then go back


Step-2 To view Maintenance order (Transaction IW39)

step-2 iw39.png

exe.PNG

list order-5.png


List of calibration order are Display, Note the Order Number from the List which where you required 


Step-3 Check & Release Maintenance order (Transaction IW32)


/wp-content/uploads/2015/06/s_20_729284.png


step-3,6.png


Step-4 Clear the Inspection lot (perform result recording & Usage decision) Transaction -QA32


step-4,7.png


Enter plant & Inspection lot origin-14 click F8 or execute


Step-5 Perform Result recording

step-5,8.png

Select Inspection lot line & click Results (pencil icon)

step-6,9.png

Enter & maintain the result

/wp-content/uploads/2015/06/s_10_729246.png

After entering result then valuate the same

/wp-content/uploads/2015/06/s_12_729260.png

/wp-content/uploads/2015/06/s_111_729247.png

Save the results.

Step-6 Perform the Usage decision for Inspection lot

Select the Inspection Lot click Usage decision (pencil icon)

S-13.png

Enter the UD code & Save

S-15.png

UD done

/wp-content/uploads/2015/06/s_16_729269.png

Step-7 Order confirmation (Transaction IW41)

/wp-content/uploads/2015/06/s_17_729270.png

Enter Order Number click Continue


/wp-content/uploads/2015/06/s_18_729281.png


Maintain the required Confirmation data.

Step-8 Technical Completion TECO order (Transaction IW32)

Enter Order Number

/wp-content/uploads/2015/06/s_20_729284.png

Continue

/wp-content/uploads/2015/06/s_21_729283.png

TECO & Save the order.

Note : while creating task list enter PM01 control key for Internal calibartion & PM02 or PM03 for external calibartion.

Thanks & Regards,

M.Arunkumar

SAP PLM Functional Consultant