In our Project we were facing lot of issue while configuring FPN between  BI producer portal and Portal Consumer .

Finally the issue is resolved but  here are some tips i want to consolidate which can help to fix the issue :-

1.We correctly configured SSO between BI producer portal and Consumer

Then also we were getting below  error  while registering fpn :-

com.sap.security.core.persistence.remote.CommunicationException: Sending request to connection ‘bi-finscm_portal’ has failed. Please check attached exception.: javax.xml.soap.SOAPException: SOAP Response Message was not well formed (java.net.SocketTimeoutException: Read timed out).

at com.sap.portal.ivs.global.roles.RemoteProducerAccessImpl.sendToRemote(RemoteProducerAccessImpl.java:545)

We tested SSO , network connectivity between both portal .

Then finally we found below RCA 

According to the following SAP Note 1718291 (Consumer Portal availability when producer Portal is down) the configuration of the ‘SOAPCallTimeout’

parameter should be set to 30000 milliseconds (30 seconds) and it was

set to 30 milliseconds (0.03 second) in our system. There for we

always get a timeout error when we try to reach the producer host.

We  configured the parameters and necessary steps as suggested in SAP Note 1718291.

Configured FPN and it worked .

Please share your experience also on FPN configurations

Regards,

Abhishek

To report this post you need to login first.

Be the first to leave a comment

You must be Logged on to comment or reply to a post.