All - Attaching files for referal. Since the limitation is for 1MB splitting them into 2 different post.
Hope this helps.
STEP 1) Create Logical system: tcode SALE - Define logical system in ECD CLNT 200 and receiving system.
STEP 2) Create Distribution model: tcode BD64
> Create Distribution Model from ECD 200 to receiving system (in this case ECE)
> Define Message Types - BOMMAT, CHRMAS, CLFMAS, CLSMAS, CNPMAS, DEPNET, ECMMAS, KNOMAS, MATMAS, UPSMAS, VFNMAS, VTAMAS, VTMMAS.
> Define BAPI - VCUI_SAVEM
STEP 3) Create Port: tcode WE21– Create Port In ECD200 system for receiving system.
STEP 4) Add RFC Destination: tcode SM59 - Create RFC Destination In ECD200 system for receiving system.
STEP 5) Create Partner Profile in Sending System (ECD200): tcode WE20
> Define receiving Logical System.
> Define Outbound Parameters - BOMMAT, CHRMAS, CLFMAS, CLSMAS, CNPMAS, DEPNET, ECMMAS, KNOMAS, MATMAS, SYNCH, UPSMAS, VCUI_SAVEM, VFNMAS, VTAMAS, VTMMAS.
> Define Inbound Parameters - UPSRCP.
STEP 6) Create Partner Profile in Receiving System: tcode WE20
> Define sending Logical System - ECD200.
> Define Outbound Parameters - N/A.
> Define Inbound Parameters - BOMMAT, CHRMAS, CLFMAS, CLSMAS, CNPMAS, DEPNET, ECMMAS, KNOMAS, MATMAS, SYNCH, UPSMAS, VCUI_SAVEM, VFNMAS, VTAMAS, VTMMAS.
You must be a registered user to add a comment. If you've already registered, sign in. Otherwise, register and sign in.