Skip to Content

I have seen in SDN forum, many of them posted

“Adapter Engine cannot be found in Integration Directory”

. We can find this error in integration directory and we can resolve this issue using the following steps.

To check the above error, go to integration directory click on menu Environment -> Cache Notification, find the below screen shot.

image

OR

While creating the communication channel for any adapter in integration directory, adapter engine will not show. Check the below screen shot.

image

Reason for getting this error :

While doing the XI post-installation steps, the technical system and business system were not created in SLD for XI server.

OR

The technical system and business system were not created properly in SLD for XI server.

Proposed solution:

Recreate the technical system and business system for XI server.

Steps to create technical system.

Step-1:

Go to tcode : RZ70

   

image

image

image

image

 

image

Important Note-1: Add the product “SAP Exchange Infrastructure 3.0” and all the SWCVs to the above technical system and business system.

Important Note-2:

Suppose while creating the business system, if you get the error message

“Integration Server already defined There is already Integration Server defined for the selected technical system . Please select role Application system.”

, then delete the technical system and recreate the technical system using RZ70 and recreate the business system based on the technical system.

There are two ways to check the adapter engine status in Integration Directory.

Go to integration directory to clear the cache , Environment -> Clear SLD Data Cache.

First:

Check the cache notification in ID , Environment menu -> Cache Notification

It should not show any error message

‘Adapter Engine not found in Integration Directory’

.

Second:

Check whether the adapter engine is showing in communication channel level for any adapter either in sender or receiver.

image

I hope this blog is very helpful to resolve the adapter engine issues.

To report this post you need to login first.

9 Comments

You must be Logged on to comment or reply to a post.

    1. Former Member Post author
      Hi Mick,

        Thanks for your comment.
      I had gone through the oss note 764176 it looks complex to resolve this issue ‘Adapter Engine cannot be found in Integration Directory’. I faced this problem in my project that is the reason I did some r & d and published so that others can resolve in a simpler way.

      Regards,
      Venu.

      (0) 
  1. Former Member
    Hi Venu,
    Thanks for the blog.
    Can you please add the category ‘SAP Basis’ along with ‘SAP PI’ to the blog.
    So the people searching for this according to category will be able to find it soon.
    Thanks!

    Ranjit

    (0) 
  2. Former Member
    i am facing the same issue in PI711. I have followed the steps you have mentioned. But is was not resolved. Please let me know is there any solution for this.
    (0) 

Leave a Reply